COMPASS Example Set Up Database (.mdb)

About COMPASS Examples
COMPASS examples are existing setups that are used as a guide to help add a new device to COMPASS.  There are 2 types of examples: those that appear directly in the DUT and/or Support Device Editors and those that do not.  Only a few examples are visible in the device editors.  This is in an attempt to minimize the confusion between various COMPASS setups.  The majority of the COMPASS examples are not directly visible to the user.  These examples are used when creating a new device.  The information below is used as a guide to updating and using examples that are not directly visible in the DUT and Support Device Editors.

Adding New Examples
With COMPASS not running, download the example database file Default.mdb and copy it to the “\Program Files\COMPASS for Pressure” directory. You must overwrite the existing Default.mdb file if present. Then run COMPASS. The examples in the default database are automatically updated in the active COMPASS database. Refer to the Updating Example Setups topic in the COMPASS Help System for more detailed information on adding the examples.  See the download "Example Setup Database" above.

Accessing an Example
Examples are accessible only when creating a new device setup (DUT, Support Device, or Piston Gauge). Follow the steps below to access a COMPASS example.
  1. Create a new device by pressing the [New] button.
     
  2. Select a model and manufacturer from the list.  The lists are composed of existing setups.
    COMPASS Example Set Up Database DeviceList Image

     
  3. Press the [Find Previous Setup] button to display the Select Example Device dialog.  This list is composed of the hidden COMPASS examples and existing setups that have the same manufacturer
    and model selections.  Double click the desired example to create a device setup based on the information in the example.
    COMPASS Example Set Up Database Select Image

     
  4. Define the specific identifying characteristics of the setup: label, identification serial number etc. Edit the raw and final output range and range unit of pressure and temperature based setups. It is important to make sure that the range and unit information matches the actual instrument. View the [Comments] tab for any extra information associated with the example. Adjust the remote interface as required by the actual test device. The example may specify IEEE-488 address 11 and the actual test instrument uses 3. In this case edit the IEEE-488 to 3 instead of 11. 
     
  5. Save the setup.  At this point the outputs most commonly used from the selected device are defined.  If an expected output is not available review the outputs provided by the example.   
    COMPASS Example Set Up Database Output Image
Supported Setups
Last updated January 13, 2011
Device Manufacturer Device Model Usage
Agilent 34401a DMM
Agilent 3458A DMM
Agilent 34970A DMM/Multiplexer
Agilent 53131A Frequency Monitor
Ametek ASC300-R Signal Calibrator/DMM
Automatic Systems Laboratories B-Series Metal Block Temperature Controller
Automatic Systems Laboratories F200 Temperature Monitor
Beamex MC5 Pressure Monitor
Crystal Engineering IS33 Pressure Monitor
Crystal Engineering XP2 Pressure Monitor
Crystal Engineering XP2i Pressure Monitor
Desgranges DPG5 Pressure Monitor
Desgranges DH300 Pressure Monitor
Desgranges DH365 Pressure Monitor
Despatch Ecosphere Temperature Monitor/Controller
Fluke Calibration FPG8601 Pressure Monitor/Controller
Fluke Calibration molbox Flow Monitor/Controller
Fluke Calibration molbox RFM Flow Monitor
Fluke Calibration PG7000 (generic) Pressure Monitor/Controller
Fluke Calibration PG7000 (Drop Rate) Pressure Monitor/Controller
Fluke Calibration PG7302 (Readings & Temp) Pressure Monitor/Controller
Fluke Calibration PG7601 Pressure Monitor/Controller
Fluke Calibration PPC1 Pressure Monitor/Controller
Fluke Calibration PPC2 Pressure Monitor/Controller
Fluke Calibration PPC2+ Pressure Monitor/Controller
Fluke Calibration PPC2AF Pressure Monitor/Controller
Fluke Calibration PPC3 Pressure Monitor/Controller
Fluke Calibration PPC3 (via AMH) Pressure Monitor/Controller
Fluke Calibration PPC4 Pressure Monitor/Controller
Fluke Calibration PPCH Pressure Monitor/Controller
Fluke Calibration PPCH-G Pressure Monitor/Controller
Fluke Calibration PPCK Pressure Monitor/Controller
Fluke Calibration PPCK+ Pressure Monitor/Controller
Fluke Calibration RPM1 Pressure Monitor
Fluke Calibration RPM3 Pressure Monitor
Fluke Calibration RPM4 Pressure Monitor
Fluke Calibration RPM4 (High RPT) Pressure Monitor
Fluke Calibration RPM4 (Low RPT) Pressure Monitor
Fluke Calibration Type 50000 Piston Gauge
Druck DPI-150 Pressure Monitor
Druck DPI-325 Pressure Monitor/Controller
(No set command)
Druck DPI-510 Pressure Monitor/Controller
Druck DPI-515 Pressure Monitor/Controller
Druck DPI-610 Pressure Monitor/Controller
(No set command)
Druck Pace 6000 Pressure Controller/Indicator
Fluke 45 DMM
Fluke 700 Series Pressure Monitor
Fluke 8808A DMM
Fluke 8845A DMM
Fluke 8846A DMM
Furness PPC500 Pressure Calibrator
GENERIC PRT Temperature Monitor
Hart Scientific 1504 Tweener Thermometer Readout
Hart Scientific 7102 Calibration Bath
Hart Scientific 1620A Dewk Thermo-Hygrometer
Heise PTE-1 Pressure Monitor
Heise PPM-2 Pressure Monitor
Keithley 2000 DMM/Multiplexer
Keithley 2001 DMM/Multiplexer
Keithley 2002 DMM/Multiplexer
Keithley 2010 DMM/Multiplexer
Keithley 2700 DMM/Multiplexer
King Nutronics 3682 Pressure Monitor/Controller
Mensor PCS400 Pressure Monitor/Controller
Mensor 410 Pressure Monitor/Controller
Mensor APC600 Pressure Monitor/Controller
Mensor 8100 Pressure Monitor/Controller
Mensor 2100 Pressure Monitor
Mensor 2300 (2310, 2320) Pressure Monitor
Mensor 2400 Pressure Monitor
Mensor 2500 Pressure Monitor
Mensor 14500 Barometer
Mensor 15000 Pressure Monitor
Mensor 6000 Pressure Transducer
Mensor 6100 Pressure Transducer
Mensor 8201 ADTS Air Data Test Set
Micro-Epsilon optoNCDT 1300 Piston Position Monitor
Mitutoyo Drop Indicator Monitor Piston Postion, Time
MKS Baratron 670 Power Supply & Readout
MKS Baratron PR4000F Power Supply & Readout
Paroscientific 760 Pressure Transmitter
Paroscientific 1000 Pressure Transmitter
Paroscientific 6000 Pressure Transmitter
Paroscientific 9000 Pressure Transmitter
Pressure Systems Quartzonix 970 Pressure Standards
Red Lion CUB5 with RS232 Board Piston Position Monitor
Rosemount Smart Family Pressure Transmitter (uses a viator RS232/HART interface)
Ruska 2455 Position, Pressure,Temperature
Monitor (deadweight monitor)
Ruska 2456 Lab Environment Monitor (LEM)
Ruska 6222 Pressure Monitor/
Ruska 7010 Pressure Monitor/Controller
Ruska 7215 Pressure Monitor/Controller
Ruska 7200 (7220, 7222, 7230, 7232) Pressure Monitor
Ruska 7250 Pressure Monitor/Controller
Ruska 7252 Pressure Monitor/Controller
Ruska 7310 Pressure Monitor/Controller
Ruska 7615 Pressure Monitor/Controller
Setra 370 Pressure Transducer
Setra 470 Pressure Transducer
Sigma Systems HARS-X-4 Temperature Monitor/Controller
Time Electronics TE5075 DMM
Vaisala PTB220 Pressure Monitor
Yokogawa MT110 Pressure Monitor